Front page >> News >>Company newspapers >> How to use Xinfan HVAC-Floor heating water separator
Details

How to use Xinfan HVAC-Floor heating water separator

The floor heating water separator is a shunt device that divides the hot water or hot steam sent from the main heating pipe into several sub-pipes to each room. It is an indispensable equipment for ground radiant heating. To a certain extent, the floor heating The water heater determines the service life of the floor heating. In order to achieve a good floor heating system circulation, the correct use of floor heating water separators is very important for the entire floor radiant heating system. From the three aspects of heating early, middle and end period, we will analyze how to use the floor heating manifold for you.


image.png



Run hot water for the first time

In the first operation, hot water should be gradually injected into the geothermal heat for the first time. When the hot water is supplied, the main loop valve of the water distributor water supply should be opened first, and the temperature of the hot water should be gradually increased and injected into the pipeline to circulate. Check whether the manifold interface is abnormal, and gradually open the branch valves of the manifold. If there is leakage in the water separator and pipeline, the main water supply valve should be closed in time and the developer or geothermal company should be contacted in time.


First run exhaust method

In the first operation of geothermal energy, air locks are easily generated due to pressure and water resistance in the pipelines, resulting in non-circulation of the supply and return water and unequal temperatures, and exhaust should be carried out one by one. As shown in the figure below, the method is: close the total return valve of heating and each loop adjustment, first open a regulating valve on the manifold, and then open the exhaust valve on the manifold's backwater bar to discharge water and exhaust. After the air is cleaned, close this valve and open the next valve at the same time. By analogy, after each air is drained, the valve is opened, and the system is officially running.


Clean the filter if the outlet pipe is not hot

A filter is installed in front of each water separator. When there are too many magazines in the water, the filter should be cleaned in time. When there are too many magazines in the filter, the water outlet pipe will not be hot, the floor heating will not be hot, etc., and the filter should usually be cleaned once a year. The method is: close all the valves on the water separator, use an adjustable wrench to open the filter end cap counterclockwise, take out the filter for cleaning, and put it back in the original after cleaning. Open the valve and the geothermal system can work normally. If the indoor temperature is lower than 1°C without heating in winter, it is recommended that the user should drain the water in the geothermal coil to prevent freezing and cracking of the pipe.

Release all the water after heating

After the annual heating period of geothermal heat is over, all the filtered pipe water in the geothermal network should be discharged. Because the boiler pipe water contains a lot of tiny particles such as slime, magazines, rust and slag, the water quality is turbid, and the inner diameter of the geothermal pipe network is very small, and the precipitation of calcium, magnesium, salt and other substances contained in the water will generate hard scale and coat the geothermal heat. On the inner wall of the pipe network, the bends are more serious, and they cannot be washed away even by pressurized water flow. This is also the reason why the floor heating needs to be cleaned. The specific cleaning steps have been described in the article "How to clean the floor heating pipes". Go into details.


skills

1. The water separator can control the heating temperature of each room or area in different ways. The user can adjust the temperature of the room according to his needs; the manual exhaust valve of the water separator allows the user to discharge the gas in the pipeline by The heating temperature of the pipeline.

2. There is a filter on the front end of the water separator. The user will remove the filter at the bottom of the filter for cleaning and install it regularly or irregularly during the annual heating period to ensure the cleanliness of the water pipe. After heating, the pipe network should be flushed with clean water.

3. When heating starts, the internal temperature will not be felt right away. During this period, the indoor ground concrete layer is gradually being heated to store thermal energy. After 2-4 days, it can reach the design temperature. For example, the user's own heating water temperature should not exceed 65°C.

4. If you are not at home for a long time, you can use the main valve of the water separator to reduce the circulating water volume, and never close it all. If the room is not heated throughout the winter, the water in the pipe should be blown out.

As a system engineering, floor heating and air conditioning are both subordinate to high-power electrical appliances, and both have their own service life. If consumers use improper methods and poor maintenance methods, they are likely to die during use. As the heart of the underfloor heating system, how to use the underfloor heating water separator and mastering a certain method of using the underfloor heating water separator can help us better use the floor heating, which not only saves money and effort for us, but also achieves a better and safer home heating effect.

A Good Life Starts With Xin!

In the development of more than 20 years, Xinfan's footprint has spread all over Germany, Italy, Ukraine, Russia, Serbia, Hungary and other European countries as well as some South American countries. Xinfan has used its strength to break the outside world's doubts about "Made in China" time and time again. Insist on putting product quality in the first place.